(661) 257-7600
|
sales@highpressuretech.com
|


|
CATALOG |
PRESSURE |
MAXIMUM OUTLET |
DISPL . PER CYCLE (IN.3)
|
CONNECTIONS
|
WEIGHT (LBS)
|
|
|
INLET
|
OUTLET
|
|||||
| PPO4 | 1:4 | 580 | 1.86 | 1 | 1/2 | 6 |
| PPO8 | 1:9 | 1,305 | 0.90 | 3/4 | 1/2 | 6 |
| PPO12 | 1:14 | 2,030 | 0.57 | 3/4 | 1/2 | 6 |
| PPO22 | 1:29 | 4,205 | 0.28 | 3/8 | 1/4 | 7 |
| PPO37 | 1:47 | 6,815 | 0.17 | 3/8 | 1/4 | 7 |
| PPO72 | 1:88 | 12,760 | 0.09 | 3/8 | 1/4 | 7 |
| PPO111 | 1:133 | 14,500 | 0.06 | 3/8 | 1/4 | 7 |
| PPO189 | 1:225 | 14,500 | 0.04 | 3/8 | 1/4 | 7 |
| NOTE: | Air drive inlet connection on all PPO pumps is 1/4″ FNPT. All connections listed are FNPT unless otherwise noted. Maximum allowable oil temperature is 140°F. Air section temperature rating: 0°F to 140°F. |
|
|
SAMPLE |
OUTLET PRESSURE (PSI) Above 35,000 psi for intermittent duty only
|
|||||||||||
|
0
|
500
|
1000
|
1500
|
2000
|
3000
|
4000
|
5000
|
7500
|
10000
|
12500
|
|||
|
PPO4
|
60
90 120 |
885
905 915 |
50 |
||||||||||
|
PPO8
|
60
90 120 |
422
430 433 |
50
240 325 |
60 |
|||||||||
|
PPO12
|
60
90 120 |
272
275 280 |
160
218 245 |
92
70 |
|||||||||
|
PPO22
|
60
90 120 |
132
136 138 |
110
126 132 |
69
108 120 |
22
82 105 |
49
85 |
30 |
||||||
|
PPO37
|
60
90 120 |
81
83 85 |
74
80 82 |
47
68 75 |
63
76 79 |
47
68 75 |
37
56 |
7
38 |
15 |
||||
|
PPO72
|
60
90 120 |
43
44 45 |
42
43 45 |
39
42 44 |
37
41 43 |
32
39 42 |
22
36 39 |
12
31 36 |
3
24 33 |
3
21 |
4 |
||
|
PPO111
|
60
90 120 |
28
29 30 |
27
28 29 |
26
28 28 |
26
27 28 |
24
27 28 |
22
26 27 |
16
24 26 |
12
22 25 |
2
16 21 |
8
16 |
10 |
|
|
PPO189
|
60
90 120 |
17
17 17 |
15
17 17 |
14
17 17 |
14
17 17 |
14
16 16 |
13
16 16 |
12
15 15 |
12
15 15 |
9
12 14 |
5
11 13 |
2
9 12 |
|
FLOW RATE IN CUBIC INCHES PER MINUTE.
MAXIMUM AIR CONSUMPTION FOR PPO PUMPS: 20 SCFM @ 90 PSI (WITH 0 PSI OUTLET).